Comparison of porcelain veneer fracture in implant-supported fixed full-arch prostheses with a framework of either titanium, cobalt-chromium, or zirconia: An in vitro study.
Märta VahnströmPetra H JohanssonPer SvanborgVictoria F StenportPublished in: Clinical and experimental dental research (2022)
Within the limitations of this study, the conclusion was that framework material may affect the fracture behavior of maxillary full-arch bridges; however, there were no differences in veneer fracture strength when frameworks of Ti, CoCr, or Y-TZP were compared.