A running suture line for aortic valve replacement does not increase the rate of postoperative complete heart block.
Ibrahim S SultanKeith A DufendachArman KilicValentino BiancoForozan NavidThomas G GleasonPublished in: General thoracic and cardiovascular surgery (2018)
Surgical implantation of a prosthetic aortic valve may be performed with a running suture technique without any significant increase in risk of heart block, need for permanent pacemaker or paravalvular leak. Long-term data will be critical to evaluate any development of paravalvular leaks in the future.