Anatomical variations of anterior ethmoidal artery and their significance in endoscopic sinus surgery: a systematic review.
Baharudin AbdullahEng Haw LimSalina HusainKornkiat SnidvongsDe Yun WangPublished in: Surgical and radiologic anatomy : SRA (2018)
The average diameter of AEA was 0.80 mm and the intranasal length was 5.82 mm. 79.2% was found between the second and third lamellae, 12.0% in the third lamella, 6% posterior to third lamella and 1.2% in the second lamella. Extra precaution should be taken in the presence of a well-pneumatized SOEC and a long LLCP as AEA tends to run freely below skull base.