Login / Signup

A Monocortical Screw for Preventing Trochanteric Escape in Extended Trochanteric Osteotomy: A Simple Solution to a Complicated Problem?

Petros IsmailidisAnnegret MündermannKarl Stoffel
Published in: Journal of clinical medicine (2023)
Extended trochanteric osteotomy (ETO) is an established method in revision total hip arthroplasty. Proximal migration of the greater trochanter fragment and the resulting non-union of the osteotomy remains a major problem, and several techniques have been developed to prevent its occurrence. This paper describes a novel modification of the original surgical technique in which a single monocortical screw is placed distally to one of the cerclages used for the fixation of the ETO. The contact between the screw and the cerclage counteracts the forces applied on the greater trochanter fragment and prevents trochanteric escape under the cerclage. The technique is simple and minimally invasive, does not require special skills or additional resources, or add to surgical trauma or operating time, and therefore represents a simple solution to a complicated problem.
Keyphrases
  • total knee arthroplasty
  • total hip arthroplasty
  • minimally invasive
  • preterm birth
  • risk assessment
  • finite element analysis
  • robot assisted