Ultrasound Cardiac Output Monitor (USCOM™) Measurements Prove Unreliable Compared to Cardiac Magnetic Resonance Imaging in Adolescents with Cardiac Disease.
Avichai WeissbachAmichay RotsteinYaniv LakovskyEytan KaplanGili KadmonEinat BirkElhanan NahumPublished in: Pediatric cardiology (2021)
The purpose of this stuy is to prospectively assess the reliability of the ultrasound cardiac output monitor (USCOM™) for measuring stroke volume index and predicting left ventricular outflow tract diameter in adolescents with heart disease. Sixty consecutive adolescents with heart disease attending a tertiary medical center underwent USCOM™ assessment immediately after cardiac magnetic resonance imaging. USCOM™ measured stroke volume index and predicted left ventricular outflow tract diameter were compared to cardiac magnetic resonance imaging-derived values using Bland-Altman analysis. Ten patients with an abnormal left ventricular outflow tract were excluded from the analysis. An adequate USCOM™ signal was obtained in 49/50 patients. Mean stroke volume index was 46.1 ml/m2 by the USCOM™ (range 22-66.9 ml/m2) and 42.9 ml/m2 by cardiac magnetic resonance imaging (range 24.7-59.9 ml/m2). The bias (mean difference) was 3.2 ml/m2; precision (± 2SD of differences), 17 ml/m2; and mean percentage error, 38%. The mean (± 2SD) left ventricular outflow tract diameter was 0.445 ± 0.536 cm smaller by the USCOM™ algorithm prediction than by cardiac magnetic resonance imaging. Attempted adjustment of USCOM™ stroke volume index using cardiac magnetic resonance imaging left ventricular outflow tract diameter failed to improve agreement between the two modalities (bias 28.4 ml/m2, precision 44.1 ml/m2, percentage error 77.3%). Our study raises concerns regarding the reliability of USCOM™ for stroke volume index measurement in adolescents with cardiac disease, which did not improve even after adjusting for its inaccurate left ventricular outflow tract diameter prediction.
Keyphrases
- left ventricular
- magnetic resonance imaging
- acute myocardial infarction
- hypertrophic cardiomyopathy
- heart failure
- cardiac resynchronization therapy
- atrial fibrillation
- mitral valve
- aortic stenosis
- left atrial
- computed tomography
- young adults
- physical activity
- end stage renal disease
- chronic kidney disease
- magnetic resonance
- ejection fraction
- contrast enhanced
- pulmonary hypertension
- blood brain barrier
- acute coronary syndrome
- transcatheter aortic valve replacement
- prognostic factors
- aortic valve
- ultrasound guided