Improved high-resolution pediatric vascular cardiovascular magnetic resonance with gadofosveset-enhanced 3D respiratory navigated, inversion recovery prepared gradient echo readout imaging compared to 3D balanced steady-state free precession readout imaging.

Animesh TandonSassan HashemiW James ParksMichael S KellemanDenver SalleeTimothy C Slesnick
Published in: Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance (2016)
Respiratory navigated 3D IR GRE imaging after GT administration provides improved vascular CMR in pediatric patients compared to pre-contrast 3D bSSFP imaging, as well as improved imaging in patients with intrathoracic metal. It is an excellent alternative in this challenging patient population when high spatial resolution vascular imaging is needed.