Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.
Stephen WarnerChristoph SommerIvan ZdericWilliam WoodburnRichard CastleJessica PenmanEladio Saura-SanchezDavid L HelfetBoyko GueorguievKarl StoffelPublished in: Archives of orthopaedic and trauma surgery (2024)
From a biomechanical perspective, lateral rim variable angle locked plating of both simple and complex patella fractures provides superior construct stability versus tension band wiring under dynamic loading.