Potential-Modulated Total Internal Reflection Fluorescence for Measurement of the Electron Transfer Kinetics of Submonolayers on Optically Transparent Electrodes.
Yilong ZhengAnthony J GiordanoSeth R MarderS Scott SaavedraPublished in: Langmuir : the ACS journal of surfaces and colloids (2020)
An electroreflectance method to determine the electron transfer rate constant of a film of redox-active chromophores immobilized on an optically transparent electrode when the surface coverage of the film is very low (<0.1 monolayer) is described herein. The method, potential-modulated total internal reflection fluorescence (PM-TIRF) spectroscopy, is a fluorescence version of potential-modulated attenuated total reflection (PM-ATR) spectroscopy that is applicable when the immobilized chromophores are luminescent. The method was tested using perylene diimide (PDI) molecules functionalized with p-phenylene phosphonic acid (PA) moieties that bind strongly to indium-tin oxide (ITO). Conditions to prepare PDI-phenyl-PA films that exhibit absorbance and fluorescence spectra characteristic of monomeric (i.e., nonaggregated) molecules were identified; the electrochemical surface coverage was approximately 0.03 monolayer. The tilt angle of the long axis of the PDI molecular plane is 58° relative to the ITO surface normal, 25° greater than the tilt angle of aggregated PDI-phenyl-PA films, which have a surface coverage of approximately one monolayer. The more in-plane orientation of monomeric films is likely due to the absence of cofacial π-π interactions present in aggregated films and possibly a difference in PA-ITO binding modes. The electron transfer rate constant (ks,opt) of monomeric PDI-phenyl-PA films was determined using PM-TIRF and compared with PM-ATR results obtained for aggregated films. For PDI monomers, ks,opt = 3.8 × 103 s-1, which is about 3.7-fold less than ks,opt for aggregated films. The slower kinetics are attributed to the absence of electron self-exchange between monomeric PDI molecules. Differences in the electroactivity of the binding sites on the ITO electrode surface also may play a role. This is the first demonstration of PM-TIRF for determining electron transfer rate constants at an electrode/organic film interface.
Keyphrases
- electron transfer
- room temperature
- carbon nanotubes
- single molecule
- particulate matter
- air pollution
- ionic liquid
- high resolution
- polycyclic aromatic hydrocarbons
- energy transfer
- heavy metals
- water soluble
- solid state
- reduced graphene oxide
- quantum dots
- healthcare
- gold nanoparticles
- dna damage response
- sensitive detection
- simultaneous determination
- capillary electrophoresis