[Reasonability of accounting for gender in intraocular lens power calculation].
Dmitrii BelovV P NikolaenkoYu Sh NizametdinovaPublished in: Vestnik oftalmologii (2023)
Patient's gender has a significant impact on IOL calculation accuracy. Using gender-responsive formulas could help achieve better refractive results with PE. The present study showed Kane formula to have the least CE dependence from gender. However, the CE difference (less than 0.25 D) was lower than the value of division (0.5D) in modern IOL models.