Can a Two Simple Stitches Method Provide Secure Fixation Strength in Biceps Tenodesis?: Biomechanical Evaluation of Various Suture Techniques.
Tae Min KimMyung Ho ShinSamuel BaekDong Ryun LeeSeok Won ChungPublished in: Clinics in orthopedic surgery (2022)
Neither the SS nor the MS method was enough to securely fix the biceps tendon with a significantly lower mechanical strength; however, the 2SS method showed similar initial fixation strength as the LL technique.