Single-center experience and evolution of technique with the E-vita Open prosthesis.
Luis Carlos Maroto-CastellanosManuel Carnero AlcazarJavier CobiellaRosa BeltraoEnrique VillagránFernando ReguilloDaniel PérezPublished in: Journal of cardiac surgery (2020)
Total arch replacement with E-vita Open hybrid prosthesis in complex thoracic aorta disease is safe. One-stage treatment is feasible when pathology does not extend beyond the proximal descending thoracic aorta. In any case, it facilitates subsequent procedures on distal aorta if needed.