Long-Term Surgical Outcomes of Glaucoma Drainage Implants in Eyes with Preoperative Intraocular Pressure Less than 19 mmHg.
Shahin HallajJae-Chiang WongLauren E HockNatasha Nayak KolomeyerAakriti Garg ShuklaMichael J ProMarlene R MosterJonathan S MyersReza RazeghinejadDaniel LeePublished in: Journal of ophthalmology (2024)
In patients with baseline IOP ≤18 mmHg who had GDI surgery, though the change in IOP was not statistically significant, the number of medications dropped and visual field progression slowed in a subset of patients with adequate perimetric data. Due to a relatively high rate of complications and limited effectiveness in lowering IOP, GDI should be cautiously used in these eyes.
Keyphrases