Login / Signup

Accuracy and Reliability of Multiphase CTA Perfusion for Identifying Ischemic Core.

Meaghan ReidAkinrinola O FamuyideNils D ForkertAron Sahand TalaiJames W EvansAmith SitaramMoiz HafeezMohamed NajmBijoy K MenonAndrew DemchukMayank GoyalRani Gupta SahChristopher D d'EsterrePhilip A Barber
Published in: Clinical neuroradiology (2018)
The assessment of mCTA-venous permits a more accurate detection of early ischemia than NCCT and mCTA-rLMC score and is predictive of clinical outcome. We would recommend the inclusion of mCTA perfusion lesion in future endovascular trials aiming at extending current AHA guidelines for EVT in stroke patients with low ASPECTS.
Keyphrases