Semitendinosus and patellar tendons shear modulus evaluation by supersonic shearwave imaging elastography.
C R C FontenellePietro MannarinoF B D O RibeiroM A MilitoA C P CarvalhoL L MenegaldoLiliam Fernandes de OliveiraPublished in: Clinical physiology and functional imaging (2018)
Semitendinosus tendon μ was significantly higher than PT μ in both tensioned and relaxed positions. This can predict a higher ultimate force to failure and a less elastic behaviour in ST grafts when compared to PT grafts. This new parameter could aid physicians in graft choice previous to anterior cruciate ligament reconstruction.