Reproducibility of point-of-care ultrasonography for central vein diameter measurement: Separating image acquisition from interpretation.

Brian P LucasAntonietta D'AddioJennifer ClarkClay BlockHarold ManningBrian RemillardJ C Leiter
Published in: Journal of clinical ultrasound : JCU (2017)
Among our investigators, central vein diameter measurements obtained by point-of-care ultrasonography are not sufficiently reproducible to distinguish clinically meaningful intravascular volume changes from measurement errors. Reproducibility could be most effectively improved by reducing the random measurement errors of acquisition. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 45:488-496, 2017.