Safety of Thermosensor Insertion in the Midline of the Spinal Canal Anterior to the Dura: A Cadaveric Study.
Julien GarnonIrène OlivierRomain LecigneMelissa FesselierDanoob DaliliPierre AulogeRoberto Luigi CazzatoJack JenningsGuillaume KochAfshin GangiPublished in: Cardiovascular and interventional radiology (2021)
Insertion of a thin blunt-tip thermosensor with optimal angulation leads to an epidural post-ligamentous position on the midline without damage to the dural sac. The blunt-tip did not prevent from dural tearing should the insertion overcross the midline.