Monitoring transcellular fluid shifts during episodes of intradialytic hypotension using bioimpedance spectroscopy.

Abdul Hamid IsmailTheresa GrossGeorg SchlieperMarian WalterFrank EitnerJürgen FloegeSteffen Leonhardt
Published in: Clinical kidney journal (2019)
The considerable discrepancy between the expected and measured loss in ECF might provide evidence of transcellular fluid shifts possibly induced by changes in plasma osmolarity due to haemodialysis. Moreover, the results suggest a pattern of fluid removal in IDH-prone patients that significantly differs from that in haemodynamically stable patients.
Keyphrases
  • end stage renal disease
  • chronic kidney disease
  • newly diagnosed
  • ejection fraction
  • peritoneal dialysis
  • body composition
  • patient reported outcomes
  • high resolution
  • mass spectrometry
  • high grade