Restorative angle of zirconia restorations cemented on non-original titanium bases influences the initial marginal bone loss: 5-year results of a prospective cohort study.
Franz-Josef StraussMarina SiegenthalerChristoph Hans Franz HämmerleIrena SailerRonald Ernst JungDaniel Stefan ThomaPublished in: Clinical oral implants research (2022)
Within the limitations of the present study, the restorative angle of implant-supported crowns on non-original titanium bases might influence the initial marginal bone loss but without affecting their favourable long-term clinical performance. A restorative angle of <40° may limit the initial marginal bone loss at implant-supported crowns with titanium bases.