Login / Signup

Capacitive Low-Frequency Hydrophone Based on Micronanostructured Iontronic Hydrogel for Underwater Monitoring.

Jiawei ZhaoQiao HuTongqiang FuHaiyang LiuYuanji YaoWenzhe ZhouZicai Zhu
Published in: ACS nano (2024)
Hydrophones play a crucial role in underwater target detection within sonar systems. However, existing hydrophones often encounter challenges such as low sensitivity and poor signal-to-noise ratio (SNR) in the detection of low-frequency acoustic signals. This work introduces a capacitive hydrophone (CH) designed for highly sensitive detection of low-frequency underwater sound signals. Comprising a latex film/silver electrode and a structured hydrogel as the electrolyte layer, the CH is enclosed in a cylindrical casing. By strategically integrating a carbon nanotube (CNT) topology network within a pyramid microarray in the hydrogel, the sensor efficiently forms the electric double layer (EDL), enhancing sensitivity and precision. The CH showcases exceptional low-pressure sensitivity across a wide frequency spectrum (20 to 800 Hz), achieving a receiving sensitivity of up to -159.7 dB in the critical low-frequency band (20 to 125 Hz), surpassing the performance of the commercial hydrophone (RHC-14) by a substantial margin of 33.29 dB. Furthermore, the CH maintains a superior SNR, enabling the detection of sound waves as faint as 0.3 Pa. This study demonstrates the capabilities of the CH in detecting maritime vessels and underwater sounds, underscoring the potential of the CNT-enhanced EDL sensing mechanism for future low-frequency hydrophone design.