Silica coated high performance oxide ceramics promote greater ossification than titanium implants: an in vivo study.

Migliorini FilippoHanno SchenkerMarcel BetschNicola MaffulliMarkus TingartFrank HildebrandSophie LecouturierBjörn RathJörg Eschweiler
Published in: Journal of orthopaedic surgery and research (2023)
HPOC implants demonstrated a greater osteoid implant contact at 6 weeks compared to the titanium implants, with no difference found at 12 weeks. The percentage of bone implant contact of HPOC implants was similar to that promoted by titanium implants.
Keyphrases
  • soft tissue
  • bone mineral density
  • postmenopausal women