Angled-tip vs. straight-tip guidewire in ERCP: a randomized, multicenter study.
Johanes HausmannFoteini LefaNatalie FilmannAxel EickhoffStefan ZeuzemEva HerrmannMarcel TantauJörg G AlbertPublished in: Scandinavian journal of gastroenterology (2022)
ERCP guidewires with an angled tip were more frequently successful when compared to straight tipped wires and most successful in treating intrahepatic strictures. Guidewires with standard vs. enhanced tip flexibility showed equal success rates in all indications.