Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws.
Chao-Hsuan ChenChih-Hsiu TuDer-Cherng ChenHsiang-Ming HuangHao-Yu ChuangDer-Yang ChoDa-Tian BauHan-Chung LeePublished in: Medicines (Basel, Switzerland) (2021)
Purpose: This study aims to elucidate the radiological outcome after Cortical bone trajectory (CBT) screw fixation and whether dual-threaded (DT) screws should be used in the fusion surgery. Methods: 159 patients with degenerative lumbar disorder who had undergone midline lumbar inter-body fusion surgery by CBT screw-fixation technique (2014 to 2018). Patient subgroups were based on single-threaded (ST) or DT screw, fixation length, as well as whether fixation involved to sacrum level (S1). Serial dynamic plain films were reviewed and an appearance of a halo phenomenon between screw-bone interfaces was identified as a case of screw loosening. Results: 29 patients (39.7%) in ST group and 10 patients (11.6%) in DT group demonstrated a halo phenomenon (p < 0.0001 ****). After subgrouping with fixation length, the incidence rates of a halo phenomenon in each group were 11.1%:3% (ST-1L vs. DT-1L), 37%:13.8% (ST-2L vs. DT-2L), and 84.2%:23.5% (ST-3L vs. DT-3L). Among the 85 patients with a fixation involved in S1, 26 patients (52%) with single-threaded screw (STS group) and 8 patients (22.8%) with dual-threaded screw (DTS group) demonstrated a halo appearance (p = 0.0078 **). After subgrouping the fixation level, the incidence of a halo appearance in each group was 25%:0% (STS-1L vs. DTS-1L), 40.9%:26.3% (STS-2L vs. DTS-2L), and 87.5%: 30% (STS-3L vs. DTS-3L). Conclusion: Both fixation length and whether fixation involved to S1 contribute to the incidence of screw loosening, the data supports clinical evidence that DT screws had greater fixation strength with an increased fixative stability and lower incidence of screw loosening in CBT screw fixation compared with ST screws. Level of evidence: 2.