Login / Signup

The utility of combined urine dipstick analysis and specific gravity measurement to determine feline proteinuria.

Jorge Pérez-AccinoL Feo BernabeE G ManzanillaJ Puig
Published in: The Journal of small animal practice (2020)
The dipstick test was not accurate for detecting proteinuria when combined with urine-specific gravity in cats. Clinicians should not rely on this test and, regardless of the urine concentration, other appropriate quantitative methods such as urine protein-creatinine ratio should always be performed to detect proteinuria in cats.
Keyphrases
  • metabolic syndrome
  • uric acid
  • loop mediated isothermal amplification
  • small molecule
  • mass spectrometry
  • amino acid
  • diabetic nephropathy