Changes in peripheral perfusion index during intraoperative end-expiratory occlusion tests do not predict the response to fluid administration in patients undergoing lung protective ventilation.
Yusuke IizukaMasamitsu SanuiYuji OtsukaKoichi YoshinagaTakeshi NakatomiAlan Kawarai LeforPublished in: Journal of anesthesia (2021)
Changes in perfusion index during intraoperative EEOT in patients undergoing lung-protective ventilation (7 ml/kg) were unable to predict the response to fluid administration.