Enabling free-breathing background suppressed renal pCASL using fat imaging and retrospective motion correction.
Isabell K BonesAnita A HarteveldSuzanne L FranklinMatthias J P van OschJeroen HendrikseChrit T W MoonenClemens BosMarijn van StralenPublished in: Magnetic resonance in medicine (2019)
Background suppression was found beneficial for free-breathing renal pCASL precision without compromising accuracy, despite motion challenges. In combination with ASLReg or FatReg, background suppression enabled clinically viable free-breathing renal pCASL.