Login / Signup

Initial validation of equilibrium contrast imaging for extracellular volume quantification using a three-dimensional engineered tissue model.

Steven BandulaTarig MagdeldinNicola StevensJason YeungJames C MoonStuart A TaylorUmber CheemaShonit Punwani
Published in: Journal of magnetic resonance imaging : JMRI (2015)
This study supports the principles of ECV estimation using equilibrium contrast MRI, but future development of this model may allow validation over a wider, more physiological ECV range and a greater understanding of the effect of tissue extracellular protein burden on ECV.