Login / Signup

Lens and Peripheral Retinal Relationships During Vitrectomy: Comparison of 23-, 25-, and 27-Gauge Vitrectomy and Curved Endolaser Probes.

Jacob S DukerMichael J VenincasaPedro F MonsalveArmando L GarciaSander R DubovyWilliam E SmiddyJayanth Sridhar
Published in: Journal of vitreoretinal diseases (2020)
Vitrectomy and curved endolaser probes achieved similar maneuverability relative to the lens regardless of gauge. This study confirms that small-gauge vitrectomy instruments have a considerable range of safe access to the peripheral retina in phakic eyes from a single sclerotomy.