Novel technique for transcatheter closure of sinus venosus atrial septal defect: The temporary suture-holding technique.
Yahia HejaziZiyad M HijaziHesham Al SaloosHaytham IbrahimGurdeep S MannYounes BoudjemlinePublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2022)
The suture technique appears to be safe modification. Although our study involves small sample size with no comparative group, we believe our technique offers greater control over stent positioning, reducing the risk of stent embolization and residual shunting in transcatheter closure of SVASD.