Woven EndoBridge versus stent-assisted coil embolization for the treatment of ruptured wide-necked aneurysms: A multicentric experience.
Aaron Rodriguez CalienesJuan Vivanco-SuarezYujing LuMilagros Galecio-CastilloBradley GrossMudassir FarooquiOktay AlğinChaim FeigenDavid J AltschulSantiago Ortega GutierrezPublished in: Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences (2024)
WEB and SAC demonstrated similar obliteration rates at follow-up when used for embolization of ruptured wide-necked IAs. However, SAC showed higher rates of procedure-related complications primarily driven by ischemic events and higher rates of EVD hemorrhage. The overall treatment duration was shorter for WEB than for SAC.