Mechanical strength of a new plate compared to six previously tested opening wedge high tibial osteotomy implants.
Arnaud Diffo KazeStefan MaasJames BelseyAlexander HoffmannRomain SeilRonald van HeerwaardenDietrich PapePublished in: Journal of experimental orthopaedics (2019)
The FlexitSystem plate showed sufficient strength for static loading, and average fatigue strength compared to the previously tested implants. Full body dynamic loading of the tibia after MOWHTO with the investigated implants should be avoided for at least 3 weeks. Implants with a wider T-shaped proximal end, positioned onto the antero-medial side of the tibia head, or inserted in the osteotomy opening in a closed-wedge construction, provided higher mechanical strength than implants with small a T-shaped proximal end, centred onto the medial side of the tibia head.