Single puncture approach guided by transesophageal echocardiography for atrial fibrillation ablation in a patient with prior percutaneous septal closure: case report.
Mário OliveiraLidia SousaAna TrindadeNogueira da SilvaPublished in: European heart journal. Case reports (2023)
In patients with ASD and an occluder device implanted, there is a potential risk for septal tear during the TSP passage, device dislodgement, or thrombus formation on the device. Atrial fibrillation ablation in this subset of patients has often been protracted and scarcely reported. TEE and intra-cardiac echocardiography have been increasingly used for interventional procedure guidance during AF ablation. As described here, AF ablation using a simplified single TSP guided by TEE is feasible, safe, and effective after device ASD closure.