Next-Day Discharge After Transcatheter Aortic Valve Implantation With the ACURATE neo/neo2 Self-Expanding Aortic Bioprosthesis.
Santiago OrdoñezMichael W A ChuPantelis DiamantourosMatthew ValdisGloria ChaumontRocio Consuelo Baro VilaPatrick TeefyRodrigo BagurPublished in: The American journal of cardiology (2024)
Previous studies have shown the safety of early discharge pathways in selected patients and using selected transcatheter heart valves. Hence, we sought to evaluate the safety of next-day discharge (NDD) in patients who underwent transfemoral transcatheter aortic valve implantation (TF-TAVI) with the ACURATE neo/neo2 (Boston Scientific, Marlborough, Massachusetts) self-expanding aortic bioprosthesis. Patients who underwent TF-TAVI between January 2018 and April 2023 were prospectively included. Patients were stratified into 3 groups according to discharge times within 24 hours (NDD), between 24 and 48 hours, and those discharged >48 hours after TAVI. The primary outcome was the first unplanned readmission at 30 days after TAVI. Log-rank test was used to assess the differences in the outcome of interest between the groups. A total of 368 all-comers were included in this study. According to discharge times, 204 patients followed NDD, 69 patients 24 to 48 hours discharge, and 95 patients >48 hours discharge after TAVI. The mean age was 84 ± 6.3 years and 61% were women, without differences between the groups. The mean Society of Thoracic Surgeons score was lower in those with NDD versus 24 to 48 hours and >48 hours (2.9 ± 1.0, 3.2 ± 1.2, and 3.4 ± 1.4, respectively, p = 0.014). There were no differences between the groups in terms of preprocedural right bundle branch block or pacemaker. The need for new permanent pacemaker implantation was the leading postprocedural complication; it occurred more frequently in the >48 hours group than the 24 to 48 hours, and <24 hours groups (24% vs 8.6% and 2.2%, p <0.001). There were 5 strokes (1.4%) and all of them occurred in the >48 hours group (p = 0.005). At 30 days after discharge, there were no deaths and no differences in all-cause readmissions (9.3% in <24 hours, 8.6% in 24 to 48 hours, and 19% in >48 hours, log-rank p = 0.087). The readmission rates for new permanent pacemaker implantation requirement were 3.3% (n = 6) in NDD, 0% in 24 to 48 hours, and 1.6% (n = 5) in the >48 hours groups (p = 0.27). In conclusion, in unselected patients who underwent TF-TAVI with the ACURATE neo/neo2 self-expanding bioprosthesis, the NDD pathway is feasible and appears to be safe, without an increased risk of death or all-cause rehospitalization through 30 days after hospital discharge.
Keyphrases
- transcatheter aortic valve implantation
- end stage renal disease
- aortic valve
- ejection fraction
- newly diagnosed
- chronic kidney disease
- peritoneal dialysis
- prognostic factors
- pregnant women
- transcatheter aortic valve replacement
- heart failure
- coronary artery disease
- type diabetes
- coronary artery
- metabolic syndrome
- skeletal muscle
- pulmonary arterial hypertension
- polycystic ovary syndrome
- vena cava
- pregnancy outcomes