Login / Signup

Computed Tomography versus Optical Scanning: A Comparison of Different Methods of 3D Data Acquisition for Tooth Replication.

Tomasz KulczykMichał RychlikDorota Lorkiewicz-MuszyńskaMonica Abreu-GłowackaAgata Czajka-JakubowskaAgnieszka Przystańska
Published in: BioMed research international (2019)
In case of teeth of noncomplicated texture, independently from a position (within or outside the alveolar socket), the high-resolution CBCT seems to be a sufficient method to obtain data for 3D printed tooth replica. Optical scanning performs better when a detailed replica is necessary.
Keyphrases