Login / Signup

Lateral Flow Immunochromatography Assay for Detection of Furosemide in Slimming Health Foods.

Yingying LiHaihuan XieJin WangXiangmei LiZhili XiaoZhen-Lin XuHong-Tao LeiXing Shen
Published in: Foods (Basel, Switzerland) (2021)
In recent years, furosemide has been found to be abused in slimming health foods. There is an urgent need for a simpler, faster method for detecting furosemide in slimming health foods. In this study, a rapid, convenient and sensitive lateral flow immunochromatography (LFIA) based on Au nanoparticles (AuNPs) was established for the first time. Under optimal conditions, the qualitative limit of detection (LOD) of the AuNPs-based LFIA was 1.0~1.2 μg/g in slimming health foods with different substrates. AuNPs-LFIA could specifically detect furosemide within 12 min (including sample pretreatment) and be read by the naked eye. The developed AuNPs-LFIA showed high consistency with liquid chromatography with tandem mass spectrometry (LC-MS/MS), and no false positive or false negative results were found in spiked slimming health foods, proving that the AuNPs-LFIA should be accurate and reliable. The AuNPs-LFIA reported here provides a serviceable analytical tool for the on-site detection and rapid initial screening of furosemide for the first time.
Keyphrases