How to hit the allergy target: A critical appraisal of intralymphatic immunotherapy with practical recommendations on ultrasound-guided injections.
Stephan FloryBjarke Hviid-VyffLara ŠošićJohannes M SchmidLars AhlbeckEmma C J WidmerClaudia C V LangKristian IkenbergThomas M KündigHans Jürgen HoffmannPål JohannsenPublished in: Allergy (2024)
Based on our results and practical experience, we propose several recommendations for LN selection and the correct handling of ultrasound probe and needle. We are confident that ILIT standardization and training will be important as to meet the goals of good safety and efficacy of ILIT.