Electrical impedance tomography-guided positive end-expiratory pressure titration in ARDS: a systematic review and meta-analysis.
Nickjaree SongsangvornYonghao XuCong LuOri RotsteinLaurent BrochardArthur S SlutskyKaren E A BurnsMirjana JerkicPublished in: Intensive care medicine (2024)
EIT facilitates real-time, individualized PEEP adjustments, improving respiratory system mechanics. Integration of EIT as a guiding tool in mechanical ventilation holds potential benefits in preventing ventilator-induced lung injury. Larger-scale studies are essential to validate and optimize EIT's clinical utility in ARDS management.