Reliability of NI-RADS criteria in the interpretation of contrast-enhanced magnetic resonance imaging considering the potential role of diffusion-weighted imaging.

Fabian Henry Jürgen ElsholtzChristoph ErxlebenHans-Christian BauknechtPatrick DinkelborgKilian KreutzerBernd HammStefan Markus Niehues
Published in: European radiology (2021)
• NI-RADS was originally designed for contrast-enhanced computed tomography with or without positron emission tomography but can also be used for contrast-enhanced magnetic resonance imaging alone. • Overall interreader agreement was acceptable for NI-RADS categories assigned to the neck but should be improved for the primary site, where it was inferior to DWI; similar tendencies were found for intrareader agreement. • DWI is currently no criterion of NI-RADS, but has shown potential to improve its reliability, especially for categories 2a, 2b, and 3 of the primary site.