Accuracy of virtual articulation in maximal intercuspal position in direct and indirect digital workflows for fixed partial denture fabrication.
Yousra EssamMohammed El KatebNoha MorsyPublished in: Journal of prosthodontics : official journal of the American College of Prosthodontists (2024)
The direct digital workflow produced significantly less linear interarch deviations in the virtually articulated models compared to the indirect digital workflow for all study groups (P < .05). However, the direct digital workflow had significantly less accuracy for virtual articulation in long span posterior, long span anterior, and short span anterior groups compared to the full dentate group. CONCLUSIONS: Both workflows produced virtually-articulated models with acceptable accuracy. However, the direct digital workflow had significantly better accuracy in all assessed clinical scenarios.