Implantation depth of balloon-expandable transcatheter heart valves and risks for permanent pacemaker implantation and midterm adverse events.
Costanza PellegriniMarkus FreißmuthTobias RheudeDavid GraasNicola Patrick MayrFinn SyrycaHector A Alvarez-CovarrubiasAndrei FetcuJudith HübnerCarsten LennerzHeribert SchunkertAdnan KastratiErion XhepaMichael JonerPublished in: Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions (2023)
Higher prosthesis implantation relative to the virtual aortic annulus was significantly associated with reduced risk for PPI at 30 days. Patients with PPI at 30 days exhibited higher mortality during follow-up, however, only logistic EuroScore, diabetes mellitus, and history of atrial fibrillation were identified as independent predictors of mortality at 2 years.