A new technique that prevents paravalvular leakage after aortic valve replacement using a rapid-deployment valve system.

Taira YamamotoDaisuke EndoHironobu YamaokaSatoshi MatsushitaKan KajimotoTohru AsaiAtsushi Amano
Published in: Journal of cardiac surgery (2021)
PVL is more likely to occur if there is a gap below the R-N commissure, especially in cases with a large annulus; therefore, applying an additional stitch to the R-N commissure is extremely useful.