Discrepancies between the one-stage clotting assay and the chromogenic assay in haemophilia B.

Kristina KihlbergK StrandbergS RosénR LjungJ Astermark
Published in: Haemophilia : the official journal of the World Federation of Hemophilia (2017)
Our findings imply that assay discrepancy occurs for factor IX activity and that both type of assays are needed for a correct diagnosis and classification of haemophilia B. The underlying mechanism by which the mutation influences the assays remains to be determined.