Characterization of Levels of Extremely Low Frequency Magnetic Fields Emitted From Portable Hand-Held Fans.

Sangjun ChoiSoyeon KimSeoyoun BaeWon KimJu-Hyun ParkEunkyo ChungSeon-Kyung ParkDong-Uk Park
Published in: Bioelectromagnetics (2019)
This study aims to assess the levels of extremely low frequency magnetic fields (ELF-MF) emitted from portable hand-held fans (HHFs) and their principal frequency and to identify factors influencing these levels. We collected a total of eleven models of HHF and monitored the ELF-MF as a function of fan speed and distance from the fan. EMDEX II was used to monitor the ELF-MF. An SMP2 EMF-meter equipped with a P400 field probe was used to determine the levels of ELF-MF and the frequency spectrum. Ten of the fans, excluding only one bladeless-fan model, emitted a high level of ELF-MF near the source of the HHF direct-current motor. The maximum measured level of ELF-MF ranged from 14.07 to 218.7 µT. All measurements of the ELF-MF taken within 10 cm from the HHFs showed values higher than 1.0 µT. ELF-MF levels were found to decrease markedly with distance, regardless of the HHF product. The level of ELF-MF rose noticeably with increased fan speed. The speed of and distance from the HHF significantly influenced the level of ELF-MF. All principal frequencies ranged from 1 to 300 Hz, which falls in the typical range of ELF. Bioelectromagnetics. 2019;40:569-577. © 2019 Bioelectromagnetics Society.
Keyphrases
  • living cells
  • fluorescent probe