Lower cost alternatives for molecular diagnosis of COVID-19: conventional RT-PCR and SYBR Green-based RT-qPCR.
Erick Gustavo DorlassCairo Oliveira MonteiroAmanda Oliveira VianaCamila Pereira SoaresRafael Rahal Guaragna MachadoLuciano Matsumiya ThomazelliDanielle Bastos AraujoFabyano Bruno LealErika Donizette CandidoBruna Larotonda TelezynskiCamila Araujo ValérioVanessa Nascimento ChalupRalyria MelloFlavia Jaqueline AlmeidaAndressa Simões AguiarAnna Carlotta Mott BarrientosCarolina SucupiraMilena De PaulisMarco Aurélio Palazzi SáfadiDaniella Gregorio Bonfim Prado SilvaJanaina Joice Martins SodréMariana Pereira SoledadeSamantha Faria MatosSabrina Rodrigues FerreiraCélia Miranda Nunez PinezCarolina Palamin BuonafineLeticia Nery Ferreira PieroniFernanda Mello MaltaRubia Anita Ferraz SantanaEloisa Corrêa SouzaRicardo Ambrosio FockJoão Renato Rebelo PinhoLuís Carlos Souza FerreiraViviane Fongaro BotossoEdison Luiz DurigonDanielle Bruna Leal de OliveiraPublished in: Brazilian journal of microbiology : [publication of the Brazilian Society for Microbiology] (2020)
In March 2020, WHO declared a pandemic state due to SARS-CoV-2 having spread. TaqMan-based real-time RT-qPCR is currently the gold standard for COVID-19 diagnosis. However, it is a high-cost assay, inaccessible for the majority of laboratories around the world, making it difficult to diagnose on a large scale. The objective of this study was to standardize lower cost molecular methods for SARS-CoV-2 identification. E gene primers previously determined for TaqMan assays by Colman et al. (2020) were adapted in SYBR Green assay and RT-PCR conventional. The cross-reactivity test was performed with 17 positive samples for other respiratory viruses, and the sensibility test was performed with 8 dilutions (10 based) of SARS-CoV-2 isolated and 63 SARS-CoV-2-positive samples. The SYBR Green assays and conventional RT-PCR have not shown amplification of the 17 respiratory samples positives for other viruses. The SYBR Green-based assay was able to detect all 8 dilutions of the isolate. The conventional PCR detected until 107 dilution, both assays detected the majority of the 63 samples, 98.42% of positivity in SYBR Green, and 93% in conventional PCR. The average Ct variation between SYBR Green and TaqMan was 1.92 and the highest Ct detected by conventional PCR was 35.98. Both of the proposed assays are less sensitive than the current gold standard; however, our data shows a low sensibility variation, suggesting that these methods could be used by laboratories as a lower cost molecular method for SARS-CoV-2 diagnosis.
Keyphrases
- sars cov
- real time pcr
- high throughput
- respiratory syndrome coronavirus
- computed tomography
- coronavirus disease
- image quality
- mass spectrometry
- transcription factor
- dna methylation
- magnetic resonance
- liquid chromatography
- nucleic acid
- liquid chromatography tandem mass spectrometry
- simultaneous determination
- label free