Login / Signup

Determination of optimal positive end-expiratory pressure using electrical impedance tomography in infants under general anesthesia: Comparison between supine and prone positions.

Ji-Hyun LeePyoyoon KangJung-Bin ParkSang-Hwan JiYoung-Eun JangJin-Tae KimJin-Tae KimHee Soo Kim
Published in: Paediatric anaesthesia (2024)
The prone position required higher positive end-expiratory pressure than the supine position in mechanically ventilated infants under general anesthesia. EIT is a promising tool to find the optimal positive end-expiratory pressure, which needs to be individualized.
Keyphrases
  • mechanical ventilation
  • intensive care unit
  • acute respiratory distress syndrome
  • magnetic resonance imaging
  • computed tomography
  • magnetic resonance
  • mass spectrometry
  • dual energy