Comparison and optimization of sheep in vivo intervertebral disc injury model.
Caroline ConstantWarren W HomDirk NehrbassEric-Norman CarmelChristoph E AlbersMoritz C DemlDominic GehweilerYunsoo LeeAndrew HechtSybille GradJames C IatridisStephan ZeiterPublished in: JOR spine (2022)
The tested IVD injury models do not all generate comparable disc degeneration but can be considered suitable IVD injury models to investigate new treatments. Results of the current study clearly indicate that slit AF defect should be avoided if disc height is used as one of the main outcomes; additional confirmatory studies may be warranted to generalize this finding.