Login / Signup

S-R difference in V1-V2 is a novel criterion for differentiating the left from right ventricular outflow tract arrhythmias.

Onur KaypakliHasan KocaDurmus Yıldıray SahinFadime KarataşSuleyman OzbicerMevlüt Koç
Published in: Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc (2017)
S-R difference in V1-V2 is a novel and simple electrocardiographic criterion for accurately differentiating RVOT from LVOT sites of ventricular arrhythmia origins. The use of this simple ECG measurement could improve the accuracy of OTVA localization, could be beneficial for decreasing ablation duration and radiation exposure. Further studies with larger patient population are needed to verify the results of this study.