Login / Signup

Response Enhancement in High-Temperature H 2 S-Treated Metal Oxide Gas Sensors.

Zijun ChenYu LiuRongyue LiuYulong ChenHongjun LiuXing Cheng
Published in: ACS sensors (2024)
Metal oxide gas sensors (MOGS), crucial components in monitoring air quality and detecting hazardous gases, are well known for their poisoning effects when exposed to certain gas molecules, such as hydrogen sulfide. Surprisingly, our research reveals that high-temperature H 2 S treatment leads to an enhancement effect rather than response decay. This study investigates the time-decaying response enhancement, being attributed to the formation of metal sulfide and metal sulfate on the metal oxide's surface, enhancing the electronic sensitization. Such an enhancement effect is demonstrated for various gases, including CO, CH 3 CH 2 OH, CH 4 , HCHO, and NH 3 . Additionally, the impacts of H 2 S treatment on the response and recovery time are also observed. Surface compositional analysis are conducted with X-ray photoelectron spectroscopy. A proposed mechanism for the enhancement effect is elaborated, highlighting the role of electronic sensitization and the sulfide-sulfate component. This research offers valuable insights into the potential applications of metal oxide sensors in sulfide-presented harsh environments in gas sensing, encouraging future exploration of optimized sensor materials, operation temperature, and the development of hydrogen sulfide poisoning-resistant and higher sensitivity MOGS.
Keyphrases
  • room temperature
  • high temperature
  • high resolution
  • low cost
  • ionic liquid
  • computed tomography
  • risk assessment
  • single molecule
  • current status
  • magnetic resonance
  • combination therapy