Despite methodologic limitations, integration of ADD-RS = 0 or ≤ 1 with DD < 500 ng/mL shows negligible heterogeneity and consistently high sensitivity across studies, thus supporting reliability for diagnostic rule-out of AASs. Data supporting ADD-RS = 0 plus DDage-adj appear preliminary and require further scrutiny.