Login / Signup

Characterization of inverted coaxial 76 Ge detectors in GERDA for future double- β decay experiments.

M AgostiniG AraujoA M BakalyarovM BalataI BarabanovL BaudisC BauerE BellottiS BelogurovA BettiniL BezrukovV BiancacciE BossioV BotheV BrudaninR BrugneraA CaldwellC CattadoriA ChernogorovT ComellatoV D'AndreaE V DemidovaN Di MarcoE DoroshkevichF FischerM FominaA GangapshevA GarfagniniC GoochP GrabmayrV GurentsovK GusevJ HakenmüllerS HemmerW HofmannJ HuangM HultL V InzhechikJ Janicskó CsáthyJ JochumM JunkerV KazalovY KermaïdicH KhushbakhtT KihmI V KirpichnikovA KlimenkoR KneißlK T KnöpfleO KochetovV N KornoukhovP KrauseV V KuzminovM LaubensteinM LindnerI LippiA LubashevskiyB LubsandorzhievG LutterC MacolinoB MajorovitsW ManeschgL ManzanillasM MiloradovicR MingazhevaM MisiaszekP MoseevY MüllerI NemchenokL PandolaK PelczarL PertoldiP PiseriA PulliaC RansomL RauscherS RiboldiN RumyantsevaC SadaF SalamidaS SchönertJ SchreinerM SchüttA-K SchützO SchulzM SchwarzB SchwingenheuerO SelivanenkoE ShevchikM ShirchenkoL ShtembariH SimgenA SmolnikovD StukovA A VasenkoA VeresnikovaC VignoliK von SturmT WesterC WiesingerM WojcikE YanovichB ZatschlerI ZhitnikovS V ZhukovD ZinatulinaA ZschockeA J ZsigmondK ZuberG Zuzelnull null
Published in: The European physical journal. C, Particles and fields (2021)
Neutrinoless double- β decay of 76 Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in 76 Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the Gerda setup. The measured resolutions at the Q-value for double- β decay of 76 Ge ( Q β β  = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (Gerda) experiment and an accumulated exposure of 8.5 kg · year, the background index after analysis cuts is measured to be 4 . 9 - 3.4 + 7.3 × 10 - 4 counts / ( keV · kg · year ) around Q β β . This work confirms the feasibility of IC detectors for the next-generation experiment Legend.
Keyphrases
  • blood pressure
  • high resolution
  • current status
  • mass spectrometry
  • image quality
  • perovskite solar cells
  • contrast enhanced
  • monte carlo