Acute biological mitral valve thrombosis after the left atrial venting in a patient with a venoarterial extracorporeal membrane oxygenator.
Kyo Seon LeeYochun JungIn S JeongSang Y SongKook J NaSang G OhPublished in: Journal of cardiac surgery (2021)
Therefore, excessive left atrial venting should be avoided. Other venting methods that can maintain the flow through the mitral valve should be considered after mitral valve replacement.